Breathlessness not only robs you of quality sleep, it can also cause multiple organ failures if the needed amount of
oxygen is compromised. Be oxygenated with our non-invasive and automatic pressure adjusting sleep breathing
treatment ventilator, intelligently engineered with responsive and intuitive sensors to monitor and adjust internal airflow
and pressure in the airway. The device can identify the patient’s current respiratory condition and define the parameters
for intervention need with adjustable or prescribed pressure setting to regulate breathing.
Neobip Bipap Vantilator
FEATURES
- Dual support: The NeoBip BiPAP ventilator provides dual support for both inhalation and exhalation, making it an effective solution for patients with respiratory conditions.
- Intelligent design: The NeoBip BiPAP ventilator is designed to be intelligent, with features such as automatic pressure adjustment and real-time monitoring.
- Customizable: The NeoBip BiPAP ventilator is customizable, with adjustable pressure levels and breathing modes to fit the patient’s specific needs.
- Easy to use: The NeoBip BiPAP ventilator is easy to use, with simple controls and a user-friendly interface.
- Comfortable: The NeoBip BiPAP ventilator is designed to be comfortable, with soft materials and adjustable straps that conform to the patient’s face.
- Improves oxygenation: The NeoBip BiPAP ventilator can help to improve oxygenation in patients with respiratory conditions, providing relief and reducing the need for more invasive treatments.
- Reduces respiratory distress: The NeoBip BiPAP ventilator can help to reduce respiratory distress, providing relief for conditions such as sleep apnea and chronic obstructive pulmonary disease (COPD).
- Non-invasive: The NeoBip BiPAP ventilator is a non-invasive option for patients seeking breathing support, minimizing the need for more invasive treatments.
- Cost-effective: The NeoBip BiPAP ventilator is a cost-effective option for patients with respiratory conditions, providing relief without the need for expensive appointments or treatments.
SPECIFICATIONS
Device Dimensions: 160mm × 148mm × 99.5mm, or 247mm × 148mm × 99.5mm (with the humidifier)
Weight: 0.82 kg, or 1.26 kg (with the humidifier)Operation, Transport and Storage
Temperature: 5 to 35°C; -20 to +60°C
Humidity: 10% to 93% Non-condensing; 10% to 93% Non-condensing
Atmospheric Pressure: 760 to 1060 hPa; 500 to 1060 hPaPneumatic flow path as shown in the diagram below:
Mode of Operation : Continuous
Mode: CPAP, AUTOS, S, ST, T, VGPS
SD Card: With a capacity ≥ 8 G, the SD card can record patient data and fault information.
AC Power adapter (Model: DA-80A24)
Input: 100-240VAC, 50-60 Hz, 2.0 A
max
Output: 24Vdc, 3.33AMain Device:
Input: 24Vdc, 3.33A max.Type of Protection Against Electric Shock: Class II Equipment
Degree of Protection Against Electric Shock: Type BF Applied Part
Degree of Ingress Protection: IP22
Pressure Range
AUTOS, ST, T, VGPS: 4 to 30 cm H2O(4 to 30 hPa)
CPAP : 4 to 20 cm H2O (4 to 20 hPa) ≤40 hPa under single fault conditions.Ramp time: The ramp time ranges from 0 to 60 minutes.
Sound Pressure Level: <30 dBA when the device is working at the pressure of 10 hPa.
Sound Power Level: <38 dBA when the device is working at the pressure of 10 hPa.
Measurement system uncertainties
In accordance with ISO 80601-2-70:2015 the measurement uncertainty of the manufacturer’s test equipment is:
For measures of flow: ±2% of reading or 0.05 Std L/min, whichever is greater
For measures of pressure: ±0.5% for full scale (15.6 – 25.6), ±1.5%for full scale (0-15.6°C 15.6 – 40°C)Pressure accuracy
Maximum static pressure variation at 10cm H2O (10 hPa) according to ISO 80601-2-70:2015 ±(0.5 hPa +5% of the set pressure)Tube
Length: 1.8m
Inner diameter: 19mm
The Form and the Dimensions of the Patient Connection Port
The 22mm conical air outlet complies
with ISO 5356-1SpO2 (Optional)
Range: 70% – 100%
Accuracy: ±3%Pluse Rate (Optional)
Range: 20-250BPM
Accuracy: ±3digitsWireless module (Bluetooth, Optional)
Frequency range: 2,402-2,480 MHz
Maximum output power: +4.0dbm
Modulation: GFSKWireless module (WiFi, Optional)
Frequency range: 2,412-2,484 MHz
Maximum output power: +20.0dbm
Modulation: CCK, OFDM