Acute respiratory challenges can be life-threatening if the amount of oxygen supply to your body is insufficient. REmediate with a nasal cannula to deliver regulated medical-grade oxygen at a flow rate of up to 80L/min. The level of oxygen concentration and humidified respiratory airflow can be adjusted to accommodate the needs of the user. Powered with highly-efficacious Particulate Matter 2.5 (PM2
BUZUD High-Flow Nasal Cannula NeoHiF-i7
FEATURES
High-flow oxygen delivery: The High-Flow Nasal Cannula i7 is designed to deliver a high-flow rate of oxygen, which can help to improve the oxygenation of patients with respiratory conditions.
Comfortable: The nasal cannula is designed to be comfortable for patients to wear, with soft nasal prongs that fit snugly into the nostrils.
Humidified oxygen: The High-Flow Nasal Cannula i7 delivers humidified oxygen, which can help to prevent dryness and irritation in the airways.
Adjustable flow rate: The device has adjustable flow rates, allowing clinicians to customize oxygen delivery to meet the specific needs of individual patients.
Easy to clean: The nasal cannula is designed to be easy to clean, with removable components that can be disinfected between uses.
Versatile: The High-Flow Nasal Cannula i7 can be used in a variety of healthcare settings, including hospitals, clinics, and home care environments.
Effective: The device has been shown to be effective in improving oxygenation in patients with respiratory conditions, reducing the need for more invasive forms of oxygen therapy.
Cost-effective: The High-Flow Nasal Cannula i7 is a cost-effective option for delivering high-flow oxygen therapy, which can help to reduce healthcare costs over time.
SPECIFICATIONS PARAMETERS
Treatment Mode: High flow mode, Low flow mode
FiO2: 21%-100% (automatic)
Dew-point temperature range: 29 – 37 deg continuously adjustable
Flow Range: Flowrate 2-80L/min
Monitored Parameters: Temperature, Flowrate, Oxygen concentration, Respiratory frequency; Optional: SpO2, Pulse rate
Trend Graph: 1, 3, 7 days trend review
Voice Alarm: Standard
Oxygen Sensor: Non consumable material
Nurse call: Standard
SPECIFICATIONS
Physical property
Dimensions: 310mmx175mmx185mm
Weight: 3 kg
Chamber capacity: ≥100ml
Tube: Length: 1.8 ± 0.18m
Environment condition
Normal operation
Temperature: 18 ~ 28 deg
Humidity: 10% – 95%, non-condensing
Atmospheric pressure: 70kPa – 106kPa
Electrical properties
Power: 100-240 VAC, 50/60 Hz, 1.5A-2.5A
Safety Type: Class II, BF
Waterproof level: IP21
Noise: When flow is 80L/min, the A-weighted sound pressure level of noise is not more than 45 dB
Chamber performance
Temperature regulation range: 29ºC to 37ºC
Air temperature at patient junction: < 43ºC
Humidifying capacity: Target temperature is 29 – 36ºC, the humidity is higher than 12 mg/L. Target temperature is 37ºC, the humidity is higher than 33 mg/L.
Heating plate power: < 160W
Regulating range of FiO2: 21% – 100%
Flow regulation range
In low flow made, setting range: 2L/min – 25L/min
In high flow made, setting range: 10L/min – 80L/min